How to Analyze HRV Data Using Kubios
Steps
ECG data
-
Open file in Kubios
-
Click "ECG" data
-
Enter the sample rate (Hz)
-
In the analysis window, double check the analysis settings by clicking on the gear icon in the tool bar
-
For a 5 minute sample, FFT settings should be 512 points, 150 s, and an overlap of 50%
-
-
Set the time frame for each sample under the sample column
-
Set to "automatic artifact correction" under the artifact correction drop down menu
-
Save results
RR data
-
Open file in Kubios
-
Click "RR" data
-
In the analysis window, double check the settings by clicking on the gear icon in the tool bar
-
For a 5 minute sample, FFT settings should be 512 points, 150 s, and an overlap of 50%
-
-
Set the time frame for each sample under the sample column
-
Set to "automatic artifact correction" under the artifact correction drop down menu
-
Save results